| ERSQ011AAV1 | |||||
|---|---|---|---|---|---|
| Dimensions | Unit | Height | mm | 1,345 | |
| Width | mm | 900 | |||
| Depth | mm | 320 | |||
| Weight | Unit | kg | 120 | ||
| Operation range | Heating | Min. | °CWB | -20 | |
| Max. | °CWB | 20 | |||
| Domestic hot water | Min. | °CDB | -20 | ||
| Max. | °CDB | 35 | |||
| Sound power level | Heating | Nom. | dBA | 68 | |
| Sound pressure level | Heating | Nom. | dBA | 52 | |
| Refrigerant | Type | R-410A | |||
| GWP | 2,087.5 | ||||
| Charge | TCO2Eq | 9.4 | |||
| Charge | kg | 4.5 | |||
| Piping connections | Liquid | OD | mm | 9.52 | |
| Gas | OD | mm | 15.9 | ||
| Drain | OD | mm | 26x3 | ||
| Level difference | IU - OU | Max. | m | 30 | |
| Heat insulation | Both liquid and gas pipes | ||||
| Standard Accessories | Installation manual | 1 | |||
| Power supply | Name | V1 | |||
| Phase | 1~ | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 220-440 | |||
| Current | Recommended fuses | A | 25 | ||
| Notes | (1) - See separate drawing for operation range | ||||
| (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | |||||
| (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | |||||
| (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase | |||||
| (5) - Contains fluorinated greenhouse gases | |||||